Centrifuge floor model refrigerated
CB1 – Centrifuge, Floor Model, Beckman Model J-6B

- Long drive and brush life
- Broad temperature range
- Easy maintenance and repair
- Built in speed calibration check
- Wide choice of rotors, tubes, and adapters
- Adjustable overtemp shutdown protection
- Minimum maintenance
- Quiet operation
Specifications:
- Maximum speed : 6000 rpm
- Minimum speed : 600 to 800 rpm
- Maximum RCF : 6840 x g
- Max. rotor capacity: 6 liters
- Braking system : electronic, variable braking
- Temp. control range : 0 to 40 ° C at full speed
- Ambient range : 16 ° C to 38 °C
Fully refurbished, with 90 day warranty.
Centrifuge, Floor Model, Refrigerated, High Speed (Supraspeed), Sorvall (Dupont), Model RC 28S

The RC-28S SUPRA speed Floor Model Refrigerated Centrifuge offers top performance for a wide range of protocols, economy in use, safety, and convenience.
Microcomputer-Controlled, the RC-28S offers speeds to 28,000 rpm and RCF to 100,500 x g. This extra performance capability enables you to perform all superspeed protocols as well as many low-end ultraspeed protocols a cost-effective alternative to operating two centrifuges.
Featuring
• Versatility:
- Achieves nearly twice the g-force of conventional superspeeds
- Can be used with most SORVALL superspeed rotors
- Full range of fixed angle and swinging bucket SUPRA speed rotors available
• Space-savings:
- Requires less floor space than conventional superspeed and ultraspeed centrifuges
- Retractable chamber door eliminates clearance problem
• Reliability:
- Unique SPIN-RIGHT rotor management system ensures safe operation and optimal control of conditions
- w 2 dt for run-to-run reproducibility
- Rotors specifically designed and independently tested for biocontainment
Max. speed
28.000 rpm
Max. RCF
100,466 x g
Max. capacity
3 liters
Several SUPRAspeed rotors have been designed to offer a combination of high speed, high g-force, and high capacity. For additional economy and versatility, most SORVALL superspeed rotors are fully functional with the RC-28S.
Fixed-angle SUPRA speed rotors: F-28/50, F-28/36, F-28/13, F-16/250
Swinging-bucket SUPRA speed rotors: S-20 (17ml), S-20 (20ml), S-20 (36ml)
Rotor recognition and safety . . . . . . . . .. SPIN-RIGHT rotor management system
Drive system . . . . . . . . . . . . . . . . . . . .. High-torque, cogless, brushless DC direct drive; 2.2kw (3hp)
Braking system . . . . . . . . . . . . . . . . . . . positive action to 0 rpm
Refrigeration system . . . . . . . . . . . . . . . high-capacity, CFC-free
Set speed range . . . . . . . . . . . . . . . . . . . 100 to 28,000 rpm
Speed control accuracy . . . . . . . . . . . .. ±10 rpm up to 2,000 rpm, ±0.5% of set speed > 2,000 rpm
Centrifuge, Floor Model, IEC, Model B-22, High Speed Refrigerated
Reach speeds of 22,000 rpm/49,300xg
For volumes up to 3L (6 x 500ml)
Large selection of rotors and adapters
| Capacity |
6 x 500m; |
| Max. Tube Size (Dia. x L) |
69.7x166mm |
| Max. Speed |
22,000rpm |
| Max. Force (rcf) |
49,300xg |
| Speed Control |
Variable |
| Timer: Range |
0 to 999 min. , Resolution 1 min. |
| Refrigerated |
Yes |
| Temperature Range |
-9° to +39°C
(+16° to +102°F) |
| Types of Rotors |
Angle, Horizontal, Basket |
| Dimensions |
86.4L x 72.4W x 109H cm
(34 x 28½ x 43?) |
| Electrical |
220-240 V, 50/60Hz |
| Warranty |
90 days |
| Condition |
Refurbished |
This model is equipped with a powerful motor, which can create forces of 49,300xg
when equipped with 05-110-07 rotor. It accommodates loads up to 3L (6 x 500ml). Two
acceleration and five deceleration rates are available to ensure gentle rotor movement and to protect your sensitive samples. And to repeat a cycle using the same parameters, simply press the Start Key. The built-in Refrigeration system maintains temperatures between –9 ° to +39 ° C within + 1 ° C. This model features automatic temperature compensation. An easy-to-read digital display helps you monitor operating conditions. Also it features cover interlock, rotor shaft protection and warning indicators for safety-hazards such as refrigeration failure, rotor imbalance, and brush wear.
|